Questions:

  • Can you test 450V high ripple current caps with a any old desktop RCL meter?
  • Has digikey shipped me faulty units?

Background:

I’ve gotten a couple of 660uF (not a typo, it’s some weird high ripple current caps for an outdoor AC unit) 450V caps to replace some that I decided were duds. Normally I only measure components when troubleshooting, but this being 20USD with vat devices I thought “what the heck, I better”.

The caps in question are chemi-con EKHJ451VSN661MA59M https://www.digikey.dk/en/products/detail/chemi-con/EKHJ451VSN661MA59M/17728502.

Method:

I’m using a Phillips PM6303A, which is a 1kHz RCL meter. Ambiant temp is approx 15°C. The caps have a 20% tolerance, so capacity should be >528uF, but when measuring both caps settle at approx 450uF after a little while. After 16hours it hasn’t deviated for the one cap I’ve left in over night. The dissipation factor, tan(δ), settled at 0.57, while the datasheet states that it shall be no greater than 0.2.

For comparison, the caps I thought was faulty, have been running for about 20years, with the same specs, but came out to 550uF and 0.3, and as the spec said 0.2 I decided to change them.

  • BigDanishGuy@sh.itjust.worksOP
    link
    fedilink
    English
    arrow-up
    1
    ·
    1 year ago

    @gondezee@lemmy.world when you say “plot a frequency sweep” what you’re looking for is just the usual voltage/time graph from a scope? No resistance in parallel to the capacitor for discharge? No fixed resistance in series? No x/y graphing funny business?

    Or are you looking for a bode plot? I was hesitant in my first response because I thought I remembered Dave doing a bode plot with a sweeping gen and a scope, but I wasn’t sure if I could find it. I could https://m.youtube.com/watch?v=uMH2hGvqhlE